Opens in a new tab

Analysis of Some Basic Parameters Related to Safety Distance Technology in PCB Manufacturing

Published: October 14, 2026 · Updated: October 14, 2026

PCBs (Printed Circuit Boards) are one of the core components of modern electronic devices. Electrical safety is always of paramount importance in the design and manufacture of PCBs. PCB safety clearances—including electrical clearance, creepage distance, and insulation penetration distance—are key factors in ensuring the proper operation of electronic devices and preventing electrical failures.

1. First, distinguish between these three types of “distance”

In the context of safety regulations, there are three types of safety distances, each characterized by different measurement paths, failure mechanisms, and methods for determining their values. Many design errors stem from confusing these three types:

  • Electrical Clearance: The shortest distance through the air, to prevent the air from being broken down and causing an arc.
  • Creepage Distance: The shortest path measured along the surface of the insulating material, preventing surface contamination and moisture from forming a leakage path (electrical tracking).
  • Distance Through Insulation: Penetrates the thickness of the solid insulation to prevent the insulation material itself from breaking down.

The relationship among the three isFind the maximum value for each requirement, not cumulative. The most common mistake in actual design is finalizing the design based solely on the electrical clearance—in humid or dusty environments, the creepage distance requirement is often more than twice the electrical clearance.

Via Pitch

2. Electrical Clearance and Creepage Distance

Electrical Clearance

Electrical clearance refers to the shortest distance between two adjacent conductors or between a conductor and the surface of an adjacent motor housing, measured through air. This distance is important because it prevents electrical short circuits and current leakage.

In the primary AC section, the distance between L and N upstream of the fuse is typically required to be greater than or equal to 2.5 millimeters, and the distance between L, N, and PE (ground) must also be greater than or equal to 2.5 millimeters. For the section connecting the primary-side AC to the DC section, the electrical clearance must be at least 2.0 mm. The distance between the primary-side DC ground and earth must be at least 4.0 mm. During design, these distances should be maintained as much as possible to prevent short circuits between electrical components and thereby ensure the safety of the power supply system.

When viewed within the context of the standards system, the value for electrical clearance is determined byOperating Voltage (including peak and transient voltages), Pollution Level, Material GroupThese three factors are taken into account collectively. The following are reference values for common operating voltage ranges (Pollution Degree 2, Material Group IIIa):

The table above shows values at steady-state operating voltages. For actual products, additional factors must be taken into account.Transient OvervoltageEffects—Lightning surges on the power grid side and spikes caused by switch operations must both be re-evaluated according to overvoltage categories (I–IV), and the larger of the two results must be taken.

Creepage Distance

Creepage distance refers to the shortest distance between two adjacent conductors or between a conductor and the surface of an adjacent motor housing, measured across the insulating surface. Similar to electrical clearance, creepage distance is intended to prevent electrical short circuits and leakage currents.

In the primary AC section, the distance between L and N upstream of the fuse must be greater than or equal to 2.5 millimeters, and the distance between L, N, and ground must also be greater than or equal to 2.5 millimeters. For the section connecting the primary-side AC to the DC section, the required creepage distance must be greater than or equal to 2.0 millimeters. These requirements ensure that electrical faults—particularly short circuits—do not occur during equipment operation, thereby maintaining electrical safety.

The calculation of creepage distance involves two more variables than that of electrical clearance:Pollution Level(Levels 1–4) andMaterial Category(Classified as I, II, IIIa, or IIIb based on the CTI relative tracking index.) At the same voltage, the worst-case combination (contamination level 3 + material group IIIb) can have requirements more than three times higher than the best-case combination (contamination level 1 + material group I):

This is also why high-voltage panels generally need to be cut open.Separation Tank—Grooving cuts off the path along the edge, forcing the current to follow the air path; this is equivalent to converting the creepage distance into an electrical clearance and is the most cost-effective method of compliance. The groove width is generally 1 mm or greater, and the depth must penetrate through the insulation layer; no copper debris should remain on the groove walls. See the CTI values and selection guidelines for common materials inPCB Materials。

3. Insulation Penetration Distance

Insulation clearance refers to the thickness of the insulation. It denotes the maximum voltage that a specific insulating component or piece of equipment can withstand during normal operation at the rated voltage. The correct selection of insulation clearance is critical to the safe operation of electronic equipment.

For operating voltages not exceeding 50 V (71 V AC peak or DC), specific insulation thickness requirements are generally not necessary. However, in other cases, the minimum thickness of the additional insulation should be 0.4 mm. This ensures that insulation failure does not occur during normal operation, thereby preventing electrical hazards.

On a PCB, the entity corresponding to "clearance" isInterlayer Dielectric Thickness. This aspect is easily overlooked because it is not explicitly labeled in the Gerber files; rather, it is determined by the layer stackup:

  • When there is insufficient single-layer media: If only a single sheet of prepreg (such as 1080, approximately 60–75 μm after lamination) is used between two layers of copper, and the circuit spans the primary and secondary high-voltage sides, two sheets of 2116 or 7628 must be used instead to increase the dielectric thickness to 150–200 μm.
  • A thin medium does not necessarily mean compliance: The standard specifies a minimum thickness requirement (typically 0.4 mm for reinforced insulation), but a single sheet of FR-4 prepreg falls far short of this. In such cases, multiple layers of dielectric material must be stacked, or an insulating sheet/barrier structure must be used instead.
  • To verify: When performing a high-potential (Hi-Pot) test, follow the product’s test voltage specifications (typically 1,500 VAC / 3,000 VDC for 1 minute, with leakage current ≤ the specified value), and slice the laminate to verify the actual dielectric thickness. For information on selecting a laminate configuration, seeHow to Choose the Right PCB Design Stack-Up Scheme。

Board Thickness and Copper Thickness in PCB Design

4. Wiring Techniques and Fire-Retardant Materials

In PCB design and manufacturing, routing techniques and material selection can also affect electrical safety. Here are some points to keep in mind:

  • For surface-mount components such as capacitors, ensure they are mounted flat; no adhesive is required.
  • If applying a force of 10 N between two conductors causes the distance between them to decrease to less than the safety code requirement, consider securing them with adhesive to maintain the electrical clearance.
  • For equipment with PVC film lining the interior of the housing, ensure that safety clearances are maintained and pay attention to the manufacturing process.
  • When applying adhesive to secure components, take care not to leave adhesive strings or other foreign objects on the PCB.

In addition, the selection of flame-retardant materials is also important to ensure that the PCB does not contribute to the spread of fire in the event of a fire. Common flame-retardant materials include heat-shrink tubing, Teflon tubing, and silicone sheets.

Expanding on the four points above, there are six actionable steps for the production line:

  • Crevice takes precedence over creepage: When designing between primary and secondary levels, prioritize creating isolation slots of at least 1 mm; this saves more space than increasing the in-plane spacing.
  • Clearance at the edge of the slot: Do not place copper, drill holes, or mount components within 0.5 mm of either side of the groove to prevent the formation of new pathways due to carbonization of the groove walls.
  • Avoid Sharp Corners: High-voltage pads and trace endpoints should be rounded or shaped like teardrops, as corona discharge can reduce the effective clearance.
  • Dispensing and Metering: Test the bond strength using a 10 N force; the amount of adhesive should be sufficient to cover 1/3 to 1/2 of the component's body. Do not allow stringing.
  • Conformal Coating: In humid environments, applying a triple-protection coating can reduce the contamination level from 3 to 2, thereby relaxing the creepage requirements; this is one of the most cost-effective ways to ensure compliance.
  • Flame Retardancy Rating: Circuit board material must meet at least UL94 V-0; FR-4 typically meets this requirement by default; halogen-free boards require separate confirmation of marking; seePCB Manufacturing Capabilities。

5. Insulation Class

The insulation class is determined based on the equipment's operating voltage and intended use. Different insulation classes provide varying levels of electrical protection. The following are some common insulation classes:

  • Operating Insulation: The insulation required for the equipment to operate normally.
  • Basic insulation: Provides basic electrical protection to prevent electric shock.
  • Supplementary insulation: In addition to the basic insulation, this provides independent insulation to prevent electric shock in the event that the basic insulation fails.
  • Double insulation: Insulation consisting of basic insulation plus supplementary insulation.
  • Reinforced insulation: Provides a level of electrical protection equivalent to double insulation, but consists of a single-layer insulation structure.

Test Requirements and Typical Applications for the Five Insulation Classes:

The key criterion is"Does a single failure cause an electric shock?": If any single layer of insulation fails, an electric shock will occur; this is considered basic insulation. If there is a second layer of insulation in place after the first fails, it is considered double or reinforced insulation. For products such as medical devices, charging stations, and photovoltaic inverters, the primary and secondary circuits are always treated as reinforced insulation.

A Comparison of the Properties of the Three Most Common Types of Rigid Copper-Clad Laminates

6. There are three more variables whose values will change

In addition to voltage and insulation class, the following three factors are often overlooked, directly causing prototypes to fail safety certification:

  • Elevation: As air density decreases with altitude, the breakdown voltage decreases. The standard value is generally based on an altitude of 2,000 m; above 2,000 m, the electrical clearance must be multiplied by an altitude correction factor (approximately ×1.14 at 3,000 m and approximately ×1.48 at 5,000 m). This must be taken into account for products exported to high-altitude regions or for aviation products.
  • Pollution Level: Class 1 (sealed or clean) → Class 2 (general indoor) → Class 3 (industrial, with conductive dust or condensation) → Class 4 (outdoor, with continuous conductive contamination). As the class level increases by one, the creepage distance requirements rise significantly.
  • Material: CTI: Standard FR-4 has a CTI rating of 175–250 V (Group IIIa), while high-CTI boards can reach over 400 V (Group II or even Group I). When manufacturing high-voltage circuit boards, selecting high-CTI materials can directly reduce the required creepage distance, making it more cost-effective than increasing the track spacing.

7. How to Choose Common Safety Standards

The recommended order of steps when selecting a model is:First, determine the product category → Determine the applicable standard → Determine the pollution degree and altitude → Determine the insulation class → Consult the table to determine clearances and creepage distances → Perform a transient overvoltage verification by superimposing transients → Optimize the design using slotting or conformal coating. Skipping any step will result in rework during the safety testing phase.

8. Four Consistency Control Points in Manufacturing

Even if the design drawings are correct, the product will still be deemed unqualified if there are deviations during manufacturing:

  • Etching Side Etching: A narrower line width after etching means a wider spacing after etching, which is beneficial for clearances but detrimental to current-carrying capacity; compensation must be made during the CAM stage rather than as a post-etch remedy.
  • Solder Mask Window Accuracy: Solder mask misalignment can expose copper, shortening the actual trace length. In high-voltage areas, the tolerance requirements for solder mask openings must be clearly defined.
  • Quality of Isolation Channels: Tolerances for slot width, carbonization of the slot walls, and residual copper in the slot must all be included in the inspection. Milling (Rout) is more suitable than V-Cut for creating safety slots.
  • Interlayer Dielectric Thickness: The actual thickness after lamination must fall within the specified range for the laminate design; this is verified through random cross-section sampling.

Multilayer Board Substrate Materials and Preforms

9. Conclusion

PCB Layer-Up Structure

PCB safety clearances are a critical factor in ensuring the electrical safety of electronic devices. The proper selection and maintenance of electrical clearance, creepage distance, and creepage distance are essential for preventing electrical failures and fires. In PCB design and manufacturing, relevant safety standards and best practices must be strictly followed to ensure the reliability and safety of the equipment.

Frequently Asked Questions

1. What are electrical clearance and creepage distance?

  • Electrical clearance is the shortest air gap between two conductors or between a conductor and the motor housing, while creepage distance is the same distance measured along the surface of the insulation.

2. Why is electrical safety clearance important?

  • Proper selection of electrical safety distances can prevent electrical short circuits, ground faults, and fires, ensuring the safe operation of electronic equipment.

3. What is an insulation class?

  • The insulation class is determined based on the equipment's operating voltage and intended use, and provides different levels of electrical protection, including working insulation, basic insulation, supplementary insulation, double insulation, and reinforced insulation.

4. Why are flame-retardant materials important?

  • Flame-retardant materials ensure that PCBs do not contribute to the spread of fire in the event of a fire, thereby improving the fire safety of electronic devices.

5. How can we ensure the electrical safety of a PCB?

  • Ensure that electrical clearances, creepage distances, and insulation penetration distances are selected and maintained correctly; follow relevant safety standards and best practices; and select appropriate flame-retardant materials.

6. What is the easiest way to fix an insufficient creepage distance?

Create an isolation groove. Mill a groove at least 1 mm wide between the two conductors to interrupt the surface path; this allows the 6 mm creepage distance requirement to be replaced by the electrical clearance value (which may be as little as 3 mm). Next, apply conformal coating to reduce the pollution level, or switch to a board with a higher CTI rating.

7. For products with a 220 V input, what is the typical spacing between the primary and secondary windings?

Based on Pollution Degree 2, Material Group IIIa, and reinforced insulation, the electrical clearance is generally ≥3.0 mm, and the creepage distance is generally ≥6.0 mm. If the product is to be exported to high-altitude regions or used in industrial environments, an altitude correction factor must be applied, and the pollution degree must be increased accordingly.

8. Do low-voltage circuits (such as 12 V) also require safety clearances?

It depends on whether it falls under the SELV (Safety Extra-Low Voltage) category. If the 12 V is generated by an isolated power supply and meets the SELV criteria, only functional insulation is required, and the clearances can be determined using the standard values for voltage and creepage; if the 12 V shares the same board with non-isolated high voltage, the 12 V side must also be isolated in accordance with the requirements for the high-voltage side.

9. What are the strict constraints on safety distances imposed by the panel plant’s process capabilities?

These four factors—minimum line width and spacing, solder mask alignment accuracy, minimum milled groove width, and interlayer dielectric thickness tolerance—directly determine whether the design’s safety margins can be achieved. Before placing an order, these parameters should be included in the drawings andPCB Manufacturing CapabilitiesCheck them one by one.

10. What are the most common causes of failure in a withstand voltage test?

Sorted by frequency of occurrence: First, insufficient interlayer dielectric thickness (layering design issue); second, residual copper or carbonization in the isolation grooves (manufacturing issue); third, flux residue or lack of conformal coating coverage along the creepage path (cleanliness issue); fourth, insufficient creepage distance in the components themselves, such as transformers and optocouplers (component selection issue). The issue can be pinpointed by troubleshooting each item one by one.

Further Reading:Electrical Safety Clearances · How to Choose the Right PCB Design Stack-Up Scheme · PCB Materials