Printed circuit boards (PCBs) play a crucial role in modern electronic devices. To ensure product quality and performance, it is important to pay attention to certain details when inspecting PCBs. In this article, we will share nine tips to help you gain a more comprehensive understanding of the PCB inspection process and how to ensure it runs smoothly.
1. Precautions for Testing Televisions, Audio Systems, and Other Devices
1.1 Avoid Contact with the Live Base Plate
When testing PCBs, never use grounded test equipment to touch live televisions, audio systems, or video equipment. In particular, when working with devices that have high output power or whose power supply characteristics are unknown, be sure to check whether the device’s chassis is live. Failure to do so may cause a power supply short circuit, which could damage integrated circuits and exacerbate the scope of the malfunction.
2. Insulation Properties of Soldering Irons
2.1 Choose a soldering iron with good insulation
When inspecting PCBs, never solder with a powered soldering iron. Make sure the soldering iron is powered, and it is best to ground the soldering iron’s casing. Extra caution is required for MOS circuits; it is best to use a low-voltage soldering iron (6–8 V) to ensure safety.
3. Understand how integrated circuits work
3.1 Understanding the Operating Principles of Integrated Circuits
Before inspecting and repairing an integrated circuit, it is essential to gain a thorough understanding of the circuit’s functions, internal circuitry, key electrical parameters, and the roles of its pins. Understanding the normal voltages and waveforms at the pins, as well as how they interact with external components, can greatly simplify the analysis and inspection process.
Advanced: The first three tips are all about preventing "further escalation of the problem."
The first three points in the original text have one thing in common: they are not intended to improve measurement accuracy, but rather to prevent the scope of the malfunction from expanding. First, never use grounded test equipment to touch live televisions, audio systems, or video equipment. Be sure to check whether the equipment’s chassis is live; otherwise, it may cause a power supply short circuit, which could damage the integrated circuits and widen the scope of the malfunction. Second, never use a live soldering iron for soldering; it is best to ground the soldering iron’s casing. Extra caution is required when working with MOS circuits; it is best to use a low-voltage soldering iron rated at 6–8 V. Third, before inspecting or repairing an integrated circuit, gain a thorough understanding of its function, internal circuitry, key electrical parameters, and the roles of its pins. Understanding the normal voltages and waveforms at the pins, as well as the operating principles of the peripheral components, can greatly simplify the analysis and inspection process.
| Entry | Requirements in the original text | Preventing Risks |
|---|---|---|
| 1. Live Base Plate | Do not use grounded test equipment to touch live equipment; check whether the base plate is live. | Power supply short circuit, failure propagation |
| 2. Soldering Iron Insulation | No need to bring a powered soldering iron; the case is grounded; use a 6–8 V low-voltage soldering iron for the MOS circuit. | The device broke down |
| 3. Understanding the Principles of ICs | First, familiarize yourself with the functions, internal circuitry, electrical specifications, and pin functions. | Analysis of Misjudgments and Invalid Cases |
| Common Characteristics | These are all part of the preparations before the test. | Avoid letting minor problems turn into major ones |
- Special care must be taken with equipment that has high output power or whose power supply characteristics are unknown.: The original text uses “especially” for emphasis;
- Grounding the soldering iron's casing is the method specified in the original text.: Not an option;
- MOS circuits were singled out: The original text specifies a low-voltage circuit;
- Normal pin voltages and waveforms serve as the basis for analysis: The original text lists this as the key to simplification;
- All three were completed before work began.: This is part of the preparation phase, not the measurement phase.

See PCBA TestingPCBA Testing; For assembly and testing, seeWhy Is PCB Assembly and Testing Necessary?。
4. Avoid short circuits between pins
4.1 Caution: Voltage Measurement
When measuring voltage or using an oscilloscope probe to test waveforms, be sure to exercise caution to avoid short circuits between integrated circuit pins caused by the test leads or probes slipping. It is best to take measurements on the peripheral printed circuit board that is directly connected to the pins to minimize the risk of accidental damage to the integrated circuit.
5. Pay attention to the internal resistance of the test instrument
5.1 Use a multimeter with an internal resistance greater than 20 kΩ/V
When measuring DC voltage across the pins of an integrated circuit, you should use a multimeter with an internal resistance greater than 20 kΩ/V to minimize the possibility of measurement errors.
6. Ensure proper heat dissipation for power integrated circuits
6.1 Focus on Heat Dissipation in Power Integrated Circuits
Power integrated circuits generate heat during operation, so it is essential to ensure proper heat dissipation. When operating at high power, a heat sink is absolutely essential.
Advanced: Four Quantitative Requirements for the Measurement Phase
The original text provides specific guidelines for the measurement process: When measuring voltage or using an oscilloscope probe to test waveforms, be sure to avoid short circuits between integrated circuit pins caused by slipping test leads or probes; it is best to take measurements on the peripheral printed circuit board directly connected to the pins; When measuring DC voltage across integrated circuit pins, select a multimeter with an internal resistance greater than 20 kΩ/V to minimize measurement error; Power integrated circuits must never operate under high-power conditions without a heat sink; If external components need to be connected to replace damaged internal parts of the integrated circuit, select small-sized components and ensure proper connections to avoid unnecessary parasitic coupling. Pay particular attention to the grounding connections between the audio power amplifier integrated circuit and the preamplifier circuit.
| Entry | Original Metrics/Methods | Purpose |
|---|---|---|
| 4. Short circuit between pins | Measurements taken on the peripheral printed circuit board directly connected to the pins | Reducing the Risk of Accidental Damage to Integrated Circuits |
| 5. Instrument Internal Resistance | A multimeter with an internal resistance greater than 20 kΩ/V | Minimize Measurement Errors |
| 6. Power IC Cooling | A heat sink is required during high-power operation. | Export Work Heat |
| 7. Lead Termination | Use small components and ensure proper connections | Avoiding Parasitic Coupling |
| 7. Special Notice | Pay attention to the ground connection between the audio amplifier IC and the preamplifier circuit | Avoid Improper Grounding |
- Before taking a measurement, make sure the test leads and probes won't slip;
- Prioritize placing components on the outer printed circuit board;
- Verify that the multimeter's internal resistance is greater than 20 kΩ/V;
- Under high-power operating conditions, check that the radiator is properly installed;
- Select a smaller replacement component and verify the ground connection.

For information on cold joints and welding defects, seeAnalysis of Causes and Solutions for PCB Soldering Defects; For welding techniques, seeWhat Are Some Tips for Soldering PCBs?。
7. Properly Route the Leads
7.1 Using Small Components
If you need to connect external components to replace damaged parts inside an integrated circuit, choose small components and ensure they are connected properly to avoid unnecessary parasitic coupling. Pay special attention to the grounding connections between the audio amplifier integrated circuit and the preamplifier circuit.
8. Ensure Welding Quality
8.1 Ensure a Secure Weld
During the soldering process, be sure to ensure a secure solder joint. Excess solder buildup and porosity can lead to cold solder joints. Soldering time should generally not exceed 3 seconds, and the soldering iron should be set to a moderate power of approximately 25W. Carefully inspect the soldered integrated circuit. It is best to use an ohmmeter to check for short circuits between the pins and ensure there is no solder bridging before applying power.
9. Do not assume that an integrated circuit is damaged without proper evaluation
9.1 Carefully Assessing Integrated Circuit Damage
Do not jump to the conclusion that the integrated circuit is damaged. Since most integrated circuits are directly coupled, a malfunction in one part may cause voltage fluctuations in multiple locations; however, these fluctuations are not necessarily caused by damage to the integrated circuit. Therefore, when determining whether an integrated circuit is functioning properly, it is necessary to consider a variety of factors comprehensively.
PCB Debugging Methods
When debugging PCBs, the following methods can help you troubleshoot issues more efficiently:
1. Observation and Initial Examination
First, when you receive a new PCB, carefully inspect it for any obvious issues, such as cracks, short circuits, or open circuits. You can also check whether the resistance between the power supply and ground is within the normal range.
2. Install the components one by one
When debugging a newly designed circuit board, it is best to install components one at a time. For standalone modules, if you are unsure whether they are functioning properly, it is best to install them in batches so you can pinpoint the source of the problem.
3. Testing the Power Supply Section
First, install the power supply section and test whether the output voltage is normal. When powering up the system, it is recommended to use an adjustable regulated power supply with current-limiting protection to prevent potential overcurrent issues. Gradually adjust the voltage while monitoring the input current, input voltage, and output voltage to ensure that the power supply section is functioning properly.
4. Install the other modules one by one
As debugging progresses, install the other modules one by one, and power up the system for testing after each installation. This helps identify design or installation errors early on to prevent component damage.
Advanced: The Three Welding Parameters and Why Defects Are Hard to Detect
The original text provides three practical guidelines for soldering: excessive solder buildup and porosity can lead to cold solder joints; soldering time should generally not exceed 3 seconds; and the soldering iron should be set to a moderate power level, around 25W. After soldering, a thorough inspection is required. It is best to use an ohmmeter to check for short circuits between the pins and ensure there is no solder bridging before applying power. Rule 9 cautions against jumping to the conclusion that an integrated circuit is damaged—since most integrated circuits are directly coupled, a malfunction in one part may cause voltage fluctuations in multiple locations, but these fluctuations are not necessarily caused by damage to the integrated circuit; a comprehensive assessment of multiple factors is required when making a judgment.
| Project | Original Values/Requirements | Note |
|---|---|---|
| Welding Time | It should generally not exceed 3 seconds. | Overheating Protection |
| Soldering Iron Power | Moderate, around 25W | Matching the Thermal Requirements of Solder Joints |
| Causes of Poor Solder Joints | Solder Buildup and Pores | A visual inspection is required |
| Post-Weld Inspection | Use an ohmmeter to check for short circuits between the pins. | Make sure there is no solder residue before turning the power back on. |
| Do not be quick to write things off as a loss | Most integrated circuits are directly coupled, so a single anomaly can cause voltage fluctuations in multiple locations. | A comprehensive assessment is required. |
- "3 seconds" and "25W" are the two most specific values in the entire text.: Can be used directly as a work standard;
- After welding, use an ohmmeter first, then turn on the power.: The order given in the original text;
- Excess material buildup and porosity are the two main causes of cold solder joints.: Parallel structure in the original text;
- Direct coupling is the technical root cause of misjudgment: The original text cites this as a reason not to readily write off a loss;
- Damages must be determined by taking multiple factors into account.: The original text concludes with the phrase “taking all factors into consideration.”

For troubleshooting poor soldering, seeCauses of Poor Soldering on PCBs and Troubleshooting Methods; See the Quality Assurance sectionQuality Assurance。
Methods for Troubleshooting
When a problem occurs, the following methods can help you quickly pinpoint the source of the problem:
1. Voltage Measurement Method
First, measure the voltages at the power supply pins of each chip to ensure they are normal. Check the various reference voltages and the operating voltages at each point. Abnormal voltages may indicate an open circuit at a pin or other issues.
2. Signal Injection Method
To troubleshoot the problem, measure the waveforms at each point along the signal source input circuit one by one. If a particular module does not respond normally, that may be the source of the problem.
3. Other Methods
You can also use your senses—such as sight, hearing, smell, and touch—to troubleshoot the problem. Check for damaged components, listen for unusual operating noises, check for strange odors, and feel for abnormal temperatures.
In summary, PCB testing is a complex and critical process that requires meticulous attention to detail. By following the tips and troubleshooting methods outlined above, you can better ensure the quality and performance of your PCBs to meet product requirements.
Advanced: The Four-Step Debugging Method and Three Types of Troubleshooting Techniques
The original text breaks down the debugging process into four steps: Upon receiving a new PCB, first carefully inspect it for any obvious issues, such as cracks, short circuits, or open circuits, and check whether the resistance between the power supply and ground is normal; when debugging a newly designed circuit board, it is best to install components step by step, installing individual modules in batches to narrow down the source of the fault; First, install the power supply section and test whether the output voltage is normal. When powering up, it is recommended to use an adjustable regulated power supply with current-limiting protection; gradually adjust the voltage while monitoring the input current, input voltage, and output voltage; then gradually install the other modules, powering up and testing after each installation to detect design or installation errors as early as possible. Three methods are provided for troubleshooting: the voltage measurement method, which involves first measuring the voltages at each chip’s power pins, the reference voltage, and the operating voltages at various points; the signal injection method, which involves injecting a signal from the input and measuring the waveforms at each point one by one; and other methods, such as visual inspection, auditory checks, olfactory checks, and tactile checks.
| Category | Original Method | Criteria |
|---|---|---|
| Debugging 1 | Observation and Initial Examination | Cracks, short circuits, open circuits; resistance between the power supply and ground |
| Debugging 2 | Install the components one by one | Install the modules in batches to determine the scope of the failure |
| Debugging 3 | Power Supply Testing | Use an adjustable regulated power supply with current-limiting protection to monitor three parameters |
| Debugging 4 | Install the other modules one by one | Power-on test after each installation |
| Troubleshooting 1 | Voltage Measurement Method | Abnormal voltage indicates an open circuit or other issue |
| Troubleshooting 2 | Signal Injection Method | If a module does not respond normally, it is considered a suspected fault point. |
| Troubleshooting 3 | Sight, Hearing, Smell, Touch | Component failure, sounds, odors, temperature |
- First, visually inspect for cracks, short circuits, and open circuits, and measure the resistance between the power supply and ground;
- Install components in batches by module;
- First, adjust the power supply by gradually increasing the voltage using a current-limited, adjustable regulated power supply;
- Power on and test the system after installing each module;
- When a malfunction occurs, first measure the voltage, then inject a signal to pinpoint the location;
- Supplemented by methods such as seeing, hearing, smelling, and touching.

See SMT Visual InspectionSMT Manufacturing Quality and Visual Inspection; For debugging instructions, seeMethods for Debugging a Newly Designed PCB Circuit。
Advanced: Quick Reference Chart for Nine Basic Principles
The original text organizes the key testing points into “9 Tips,” covering everything from pre-test preparation and measurement techniques to soldering and fault diagnosis. By rearranging them in the order they should be performed, you can quickly review them before each power-up to ensure you don’t overlook any steps that, if done incorrectly, could cause the scope of the malfunction to expand.
| Order | Original entry | Key Moves |
|---|---|---|
| 1 | Precautions for Testing Televisions, Audio Systems, and Other Devices | Check whether the base plate is live |
| 2 | Insulation Properties of Soldering Irons | Ground the casing; use a 6–8 V low-voltage soldering iron for the MOS circuit. |
| 3 | Understanding How Integrated Circuits Work | Understand Normal Pin Voltages and Waveforms |
| 4 | Avoid short circuits between pins | Measurements on Peripheral Printed Circuit Boards |
| 5 | Pay attention to the internal resistance of the test instrument | The multimeter's internal resistance is greater than 20 kΩ/V |
| 6 | Ensuring Heat Dissipation for Power Integrated Circuits | A heat sink must be installed when operating at high power. |
| 7 | Proper Handling of Leads | Small components—pay attention to the ground terminal |
| 8 | Ensuring Welding Quality | Solder for no more than 3 seconds using a soldering iron rated at approximately 25W. |
| 9 | Do not jump to conclusions about integrated circuit damage | Direct coupling can cause voltage fluctuations in multiple locations. |
- The first two measures are intended to prevent safety incidents.: A live base plate and a live soldering iron;
- The three middle ones account for measurement errors.: Short circuits, internal resistance, heat dissipation;
- Articles 7 and 8 address manufacturing defects.: Parasitic coupling and cold solder joints;
- Article 9: Preventing Misjudgments: The original text clearly states, “Do not jump to conclusions”;
- The Three Highest Values in the Entire Text: 20 kΩ/V, 3 seconds, 25 W.
- Check the condition of the circuit board and the soldering iron;
- Review the circuit diagram and pin specifications of the IC to be tested;
- Select the appropriate meter and verify the internal resistance;
- Inspect the power IC heat sink;
- Press for 3 seconds and complete the weld at 25W;
- After welding, use an ohmmeter to check for short circuits before restoring power.


Common design errors can be found atHow to Avoid Common Mistakes in Printed Circuit Board Design; For PCB manufacturing, seePCB Manufacturing。
Frequently Asked Questions
1. How can you prevent short circuits when testing PCBs?
When testing PCBs, exercise caution when using a multimeter or oscilloscope to ensure that the test leads or probes do not slip and cause a short circuit between the pins of an integrated circuit. It is best to take measurements on the outer printed circuit.
2. How can we ensure welding quality?
During the soldering process, ensure a secure solder joint and avoid solder buildup and pinholes to prevent cold solder joints. Use a soldering iron with the appropriate power setting, and the soldering time should not exceed 3 seconds.
3. How can you tell if an integrated circuit is damaged?
Do not jump to the conclusion that the integrated circuit is damaged, as various factors within the circuit can cause voltage fluctuations. Carefully analyze the circuit and consider potential issues from multiple angles.
4. How do you troubleshoot a problem?
Faults can be identified using methods such as voltage measurement, signal injection, as well as visual inspection, auditory detection, olfactory detection, and tactile inspection. A step-by-step troubleshooting process can help pinpoint the source of the fault.
5. Why is it necessary to install modules one by one for debugging?
Installing modules one by one helps pinpoint the scope of the problem and avoids the difficulty of troubleshooting when issues occur simultaneously across the entire circuit board. This approach facilitates a more systematic problem-solving process.
6. What precautions should be taken when testing TVs and audio equipment that are plugged in?
The original text states that you must never use a grounded test device to touch live televisions, audio systems, or video equipment. This is especially important when working with devices that have high output power or whose power supply characteristics are unknown; you must always verify whether the device’s base plate is live, as failure to do so may cause a power supply short circuit and exacerbate the scope of the malfunction.
7. What type of meter should be used to measure DC voltage across the pins of an integrated circuit?
The original text specifies that a multimeter with an internal resistance greater than 20 kΩ/V should be selected to minimize the possibility of measurement errors.
8. How should power be applied to the power supply section during debugging of a new board?
The original text recommends installing the power supply section first and testing whether the output voltage is normal. When powering up, use an adjustable regulated power supply with current-limiting protection, and gradually adjust the voltage while monitoring the input current, input voltage, and output voltage.
Related Reading:Methods for Debugging a Newly Designed PCB Circuit · How to Avoid Common Mistakes in Printed Circuit Board Design